  Datasheet File OCR Text:
 Surface-mounting Relay
G6J-Y
Ultra-compact and Slim DPDT Relay
* Dimensions of 9H x 5.7W x 10.6L mm provide a mounting area reduction of approx. 56% when compared with the OMRON G6S. * Dielectric strength of 1,500 VAC and an impulse withstand voltage of 2,500 V for 2 x 10 s (conforms to Telcordia specifications (formerly Bellcore)). * Conforms to FCC Part 68 requirments (1,500 V,10 x 160 s). * Single-winding latching models to save energy. * UL recognized / CSA certified. * RoHS Compliant.
Ordering Information
Item Terminal PCB through-hole SMT Gull-wing SMT Shortened leads
.
Model Non-latching G6J-2P-Y G6J-2FL-Y G6J-2FS-Y Single coil latching G6JU-2P-Y G6JU-2FL-Y G6JU-2FS-Y
Contact form DPDT
Note 1: When ordering, add the rated coil voltage to the model number. Example: G6J-2P-Y DC12 Rated coil voltage Note 2: When ordering tape packing, add "-TR" to the model number. Example: G6J-2P-Y-TR DC12 Rated coil voltage "-TR" is not part of the relay model number. Therefore it is not marked on the relay case.
Model Number Legend:
G6J 1 23 -Y 4 DC 5
4. Packaging None: Tube packaging TR: Tape and reel packaging 9. Rated Coil Voltage 3, 4.5, 5, 12, 24
1. Relay Function None: Non-latching, standard U: Single-winding latching 2. Contact Form 2: DPDT 3. Terminal Shape P: PCB through-hole terminals FL: SMT Gull-wing FS: SMT shortened leads
Application Examples
Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products.
Surface-mounting Relay
G6J-Y
57
Specifications
Contact Data
Rated load Contact material Max. carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load (see note) 0.3 A @ 125 VAC 1 A @ 30 VDC Ag (Au Clad) 1A 125 VAC, 110 VDC 1A 37.5 VA, 30 W 10m VDC, 10A
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 5% of the load impedance. This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always doublecheck relay suitability under actual load conditions.
Coil Data
G6J-Y Standard, Non-latching (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y)
Rated voltage (VDC) 3 4.5 5 12 24 Rated current (mA) 48.0 32.6 28.9 12.3 9.2 Coil resistance Pick-up voltage () 62.5 137.9 173.1 976.8 2,600.5 230 75% max. Drop-out voltage % of rated voltage 10% min. 150% max. 140 Max. voltage Power consumption (mW)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y)
Rated voltage (VDC) 3 4.5 5 12 Rated current (mA) 33.7 22.0 20.4 9.0 Coil resistance () 89.0 204.3 245.5 1,329.2 Set voltage 75% max. Reset voltage % of rated voltage 75% max. 150% max. Max. voltage Power consumption (mW) 100
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
58
Surface-mounting Relay
G6J-Y
Characteristics
Item Contact resistance (See note 1) Operating (set) time (See note 2) Release (reset) time (See note 2) Minimum set/reset pulse width Insulation resistance (See note 3) Dielectric strength Standard non-latching relays G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y 100 m max. 3 ms max. (approx. 1.6 ms) 3 ms max. (approx. 1.0 ms) --1,000 M min. (at 500 VDC) 1,500 VAC, 50/60 Hz for 1 min. between coil and contacts 1,000 VAC, 50/60 Hz for 1 min. between contacts of different polarity 750 VAC, 50/60 Hz for 1 min. between contacts of the same polarity Surge withstand voltage Vibration Shock Service life Mechanical durability Malfunction durability Mechanical durability Malfunction durability Mechanical Electrical Ambient temperature Humidity Weight Note: 1. 2. 3. 4. 2,500 VAC, (2 x 10 s) between coil and contacts 1,500 VAC, (10 x 160 s) between contacts of the same and different polarity 10 to 55 Hz, 5-mm double amplitude 10 to 55 Hz, 3.3-mm double amplitude 1,000 m/s2 (approx. 100G) 750 m/s2 (approx. 75G) 50,000,000 operations min. (at 36,000 operations/hour) 100,000 operations min. (with a rated load at 1,800 operations/hour) -40 to 85C with no icing or condensation 5% to 85% RH Approx. 1.0 g The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. Values in parentheses are typical values unless otherwise stated. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the dielectric strength. The above values are initial values. 3 ms max. (approx. 0.9 ms) 10 ms min. (at 100% rated coil voltage) Single coil latching relays G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Surface-mounting Relay
G6J-Y
59
Characteristic Data
Maximum Switching Capacity
Switching current (A) 10 7 5 3
Ambient Temperature vs. Maximum Voltage
Maximum voltage (%) 250
Ambient Temperature vs. Switching Current
Switching current (A)
1.2
200
1
0.8
150 0.6 100
AC resistive load 1 0.7 0.5 0.3 DC resistive load
0.4 50
0.2
0.1
1
3
5
10
30 50
100
300 500 1,000
0 -40
-20
0
20
40
60
80
100
0 -40
-20
0
20
40
60
80
100
Switching voltage (V)
Ambient temperature (C)
Ambient temperature (C)
Note:
"Maximum voltage" is the maximum voltage that can be applied to the Relay coil.
Electrical Life Expectancy
Switching operations (x104 operations) 1,000 500 300
Ambient Temperature vs. Must Shock Malfunction Operate or Must Release Voltage
Change rate on the basis of rated voltage (%) 100 90 80 70 60 50 200 40 30 20 10 Operating voltage Release voltage -40 -20 0 20 40 60 80 100 max. avg. min. 1,000 Z' Shock directions X X' Y Z Z' Y' 400 600 800 1,000 Unit: m/s2 Sample: G6J-2P-Y Number of Relays: 10 1,000 X' Maximum estimated value max. avg. min. Y 1,000 800 X 1,000 600 Not energized 400 200 Z 1,000 Energized
100 50 30
30 VDC resistive load Ambient temperature: 23C Switching frequency: 1,800 operations/hour
10 5 3 125 VAC resistive load Ambient temperature: 23C Switching frequency: 1,800 operations/hour
Y'
1 0
0.2
0.4
0.6
0.8
1
1.2
0 -60
Switching current (A)
Ambient temperature (C)
Conditions: Shock is applied in X, Y, and Z directions three times each with and without energizing the Relays to check the number of contact malfunctions.
Electrical Life Expectancy (with Must Operate and Must Release Voltage) (See note.)
On the basis of rated voltage (%) 100 Sample: G6J-2P-Y
Number of Relays: 10 Test conditions: 1-A resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/hour
Electrical Life Expectancy (Contact resistance) (See note.)
Contact resistance (m)
Sample: G6J-2P-Y Number of Relays: 10 Test conditions: 1-A resistive load 500 at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/hour
Contact Reliability Test (See note.)
Contact resistance (m) 1,000
Sample: G6J-2P-Y Number of Relays: 10 Test conditions: 10 A resistive load 500 at 10 m VDC with an operation rate of 50% Switching frequency: 7,200 operations/hour
1,000 NO contact NC contact
NO contact NC contact
80
max. min.
300
300
60
Operate voltage
100 max. 40 min. Release voltage 20 50 30 Contact resistance max. max. min. min.
100 max. max. 50 30 Contact resistance min. min.
0 0.001 0.01
0.1
1
10 (x103
100
1,000
10 0.001 0.01
0.1
1
10
3
100
1,000
10 0.001 0.01
0.1
1
10
100
1,000
Operating frequency
operations)
Operating frequency (x10 operations)
Operating frequency (x105 operations)
Note:
1. 2.
The tests were conducted at an ambient temperature of 23C. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use
60
Surface-mounting Relay
G6J-Y
Mutual Magnetic Interference
Change rate on the basis of initial value (%)
Initial stage Installed in flush configuration
Mutual Magnetic Interference
Change rate on the basis of initial value (%)
Initial stage Installed in flush configuration
+30 +20 +10 0 -10 -20 -30 +30 +20 +10 0 -10 -20 -30
Average value Initial stage Average value Installed in flush configuration
+30 +20 +10 0 -10 -20 -30 +30 +20 +10 0 -10 -20 -30
Average value Initial stage Average value Installed in flush configuration
Sample Not energized
Sample
Not energized
Change rate on the basis of initial value (%)
Sample Energized
Sample
Energized
Change rate on the basis of initial value (%)
Set voltage Reset voltage
Set voltage Reset voltage
External Magnetic Interference
Average value
Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) +30 S +20 N +30 S +20 N
Average value
Change rate on the basis of initial value (%) +30 S +20 N
Average value
+10
+10
+10
0
0
0
-10
-10
-10
-20 -30 -1,200
Sample: G6J-2P-Y Number of Relays: 5
-800 -400 0
Must Operate voltage Must Release voltage 400 800 1,200
-20 -30 -1,200
-20
Sample: G6J-2P-Y Number of Relays: 5
-800 -400 0
Must Operate voltage Must Release voltage 400 800 1,200
-30 -1,200
Sample: G6J-2P-Y Number of Relays: 5
-800 -400 0
Must Operate voltage Must Release voltage 400 800 1,200
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
High-frequency Characteristics High-frequency Characteristics High-frequency Characteristics (Return Loss, V.SWR) (Insertion Loss) (Isolation)
Average value
10 20 30 2 poles 40 50 60 70 80 90 100 1 2.5 10 100 1,000 1 10 100 1,000 Frequency (MHz) Frequency (MHz) 70 1 10 100 1,000 Frequency (MHz) 0 2 60 1 pole 40 1.5 50 2-pole V.SWR 1-pole V.SWR 0.5 1 1.5
Average value Insertion Loss (dB)
0
Average value
Isolation (dB)
0
Return loss (dB)
10
3
0.5 1 pole 1
20 2-pole return loss 30
2.5
2 poles
1-pole return loss
2
Note: 1. The tests were conducted at an ambient temperature of 23C. 2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including endurance, in the actual machine before use.
Surface-mounting Relay
G6J-Y
V.SWR
0
3.5
61
Must Operate and Must Release Must Operate and Must Release Bounce Time Distribution Time Distribution (See note.) (See note.)
Number of contacts Number of contacts Number of contacts 40 35 30 25 20 15 10 5 Sample: G6J-2P-Y Number of Relays: 30 Must Operate time Must Release time 40 40 35 35 30 30 25 25 20 20 15 15 10 10 5 5 0 0 0.5 0.5 1 1 1.5 1.5 Sample: G6J-2P-Y Sample: G6J-2P-Y Number of Relays: 30 Number of Relays: 30 2 2.5 3 2 2.5 3 Time (ms) Time (ms) Must Operate bounce time Must Operate bounce time Must Release bounce time Must Release bounce time
Vibration Resistance
5.0 Change rate on the basis of rated value (%) 4.0 3.0 2.0 1.0 Must Operate voltage 0.0 -1.0 -2.0 -3.0 -4.0 -5.0 Initial After Must Release voltage
0
0.5
1
1.5
2
2.5
3
Time (ms)
Note:
The tests were conducted at an ambient temperature of 23C.
62
Surface-mounting Relay
G6J-Y
Dimensions
Note: All units are in millimeters unless otherwise stated. A tolerance of 0.3 (0.01) applies to every dimension in the following drawings unless otherwise stated.
G6J-2P-Y G6JU-2P-Y
10.6 5.7
Mounting Dimensions (Bottom View)*
7.6 5.4 3.2
Terminal Arrangement Internal Connections (Bottom View)
G6J-2P-Y
9
Eight, 0.85-dia. holes
Orientation mark
1 + 2 3 4
3.5
0.3 1.5 3.2 5.4 7.6 0.4 3.2 0.15 (1.5) (1.25)
3.2 - 8 7 6 5
*Tolerance 0.1 mm
G6JU-2P-Y Orientation mark
1 +- SR -+ 8 7 6 5 2 3 4
G6J-2FS-Y G6JU-2FS-Y
10.6 5.7
Mounting Dimensions (Top View)*
7.6 5.4 3.2
Terminal Arrangement/ Internal Connections (Top View)
G6J-2FS-Y Orientation mark
2.35 8 7 - + 6 5
10.0 max. 4.35
1.5 3.2 5.4 7.6
0.4
3.2 5.7
0.8 (1.5)
1
2
3
4
*Tolerance 0.1 mm
G6JU-2FS-Y Orientation mark
8 -+ SR +- 1 2 3 4 7 6 5
G6J-2FL-Y G6JU-2FL-Y
10.6 5.7
Mounting Dimensions (Top View)*
7.6 5.4 3.2
Terminal Arrangement/ Internal Connections (Top View)
G6J-2FL-Y Orientation mark
3.2
8 - 5.2 1 +
7
6
5
10.0 max.
1.5 3.2 5.4 7.6
0.4
3.2 7.4 0.8 (1.5)
2
3
4
*Tolerance 0.1 mm
G6JU-2FL-Y Orientation mark
8 -+ SR +- 1 2 3 4 7 6 5
Surface-mounting Relay
G6J-Y
63
Stick Packing and Tape Packing
1. Stick Packing
Relays in stick packing are arranged so that the orientation mark of each Relay is on the left side. Always confirm that the Relays are in the correct orientation when mounting the Relays to the PCBs.
Orientation of Relays Stopper (gray) Stopper (green)
Carrier Tape Dimensions
G6J-2FS-Y, G6JU-2FS-Y
20.1 160.1 40.1 10.20.1 A B 1.5 +0.1 dia. 0 1.750.1 0.40.05
11.50.1 240.2 11.10.1 6.30.1
B
5 max. B-B Cross Section
Stick length: 555 mm (stopper not included) No. of Relays per stick: 50
A
6.20.1
8.30.1 5 max. A-A Cross Section
5 max.
2. Tape Packing (Surface-mounting Terminal Relays)
When ordering Relays in tape packing, add the prefix "-TR" to the model number, otherwise the Relays in stick packing will be provided. Tape type: Reel type: Relays per reel: TB2412R (EIAJ (Electronic Industrial Association of Japan)) R24D (EIAJ (Electronic Industrial Association of Japan)) 400
20.1 160.1 40.1
G6J-2FL-Y, G6JU-2FL-Y
10.20.1 A B 1.5 +0.1 dia. 0 1.750.1 0.40.05
11.50.1 240.2 11.10.1 6.30.1
Direction of Relay Insertion
Pulling Direction Orientation mark Top tape (cover tape) Pulling direction
B A 7.90.1 100.1 5 max.
5 max. B-B Cross Section
5 max.
A-A Cross Section
Carrier tape
Embossed tape
Reel Dimensions
25.50.5 29.51 130.2 dia. 20.5 210.5 dia.
A 330 80
R1
Enlarged View of Section A
64
Surface-mounting Relay
G6J-Y
Recommended Soldering Method
IRS Method (for Surface-mounting Terminal Relays)
Temperature (C)
250 max. 230 180
Top of cover (Peak): 255C max. Soldering
* The thickness of cream solder to be applied should be between 150 and 200 m on OMRON's recommended PCB pattern. * In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left-hand side. Correct Soldering
Relay Terminal Solder Land
Incorrect Soldering
Insufficient amount of solder Excessive amount of solder
PCB
150 Preheating
Visually check that the Relay is properly soldered.
Surface of the relay terminal
120 max.
30 max. Time (s)
Note: Temperatures are given for the surface of the terminal.
Approved Standards
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40C
Contact form DPDT Coil rating Contact rating Number of test operations 6000 G6J-2P-Y, 2FS-Y, 2FL-Y: 3 to 24 VDC 1 A at 30 VDC (Resistive) G6JU-2P-Y, 2FS-Y, 2FL-Y: 3 to 24 VDC 0.5 A at 60 VDC (Resistive) 0.3 A at 125 VAC (General purpose)
Surface-mounting Relay
G6J-Y
65
Precautions
Correct Use
Long Term Current Carrying
Under a long-term current carrying without switching, the insulation resistance of the coil goes down gradually due to the heat generated by the coil itself. Furthermore, the contact resistance of the Relay will gradually become unstable due to the generation of film on the contact surfaces. A Latching Relay can be used to prevent these problems. When using a non-latching relay, the design of the fail-safe circuit provides protection against contact failure and open coils.
Maximum Voltage
The maximum voltage of the coil can be obtained from the coil temperature increase and the heat-resisting temperature of coil insulating sheath material. (Exceeding the heat-resisting temperature may result in burning or short-circuiting.) The maximum voltage also involves important restrictions. Maximum voltage: * must not cause thermal changes or deterioration of the insulating material. * must not cause damage to other control devices. * must not cause any harmful effect on people. * must not cause fire. Therefore, be sure not to exceed the maximum voltage specified in the catalog. As a rule, the rated voltage must be applied to the coil. A voltage exceeding the rated value, however, can be applied to the coil provided that the voltage is less than the maximum voltage. It must be noted that continuous voltage application to the coil will cause a coil temperature increase which could deteriorate the coil insulation, shorten the relay's electrical life, or affect various characteristics of the relay.
Handling of Surface-mounting Relays
Use the Relay as soon as possible after opening the moisture-proof package. If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and seal the package with adhesive tape. When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature at less than 40C. Do not put the relay in a cold cleaning bath immediately after soldering.
Coating
Relays mounted on PCBs may be coated or washed. Do not apply coatings or detergents containing silicone.
Soldering
Solder: JIS Z3282, H63A Soldering temperature: Approx. 250C (At 260C if the DWS method is used.) Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and approx. 3 s for the second time if the DWS method is used.) Be sure to adjust the level of the molten solder so that the solder will not overflow onto the PCB.
Other Handling
Dropping the relay may impose excess shock that exceeds the specifications. Do not use any relay that has been dropped.
Claw Securing Force During Automatic Insertion
During automatic insertion of Relays, make sure to set the securing force of the claws to the following values so that the Relay characteristics will be maintained.
C A B
Direction A: 4.90 N max. Direction B: 9.80 N max. Direction C: 9.80 N max. Secure the claws to the area indicated by shading. Do not attach them to the center area or to only part of the Relay.
Environmental Conditions During Operation, Storage, and Transportation
Protect the Relays from direct sunlight and keep the Relays under normal temperature, humidity, and pressure.
Mounting Latching Relays
The Latching Relays are reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relays may be set accidentally. Be sure to apply a reset signal before use. Make sure that the vibration or shock that is generated by other devices on the same panel does not exceed the rated value of the Latching Relays.
66
Surface-mounting Relay
G6J-Y
Omron Electronic Components, LLC
Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER'S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER'S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference.
(b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller's practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller's website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision.
Surface-mounting Relay
G6J-Y
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information.
Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC COMPONENTS LLC
55 E. Commerce Drive, Suite B Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1 06/09 Specifications subject to change without notice Printed in USA
Surface-mounting Relay
G6J-Y


▲Up To Search▲   

 
Price & Availability of G6J-2FL-Y

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X